First, check the power, switch and opener motor.
If they work but the shaft does not turn, then check the coupler.
The coupler assembly is designed to keep the screw drive and motor from wear and tear.
It can get fatigued over time with the weight of your garage door.
Then it’s time to replace the screw drive coupler with this replacement.
Universal Compatibility
Replaces sprocket coupler part number: 025C0020, 25A20, 25C20, 025C0020, 25A18
Compatible with Liftmaster, Sears, Craftsman and Chamberlian screw drive and low profile screw drive operators (1995-current)
Compatible with Liftmaster models 1000SD, 2000SD, 1000SDR, 2000SDR, 2110, 2220
Compatible with Chamberlain models 4600, 4620, 4640, 9902, PD420, PD460-2, 9950
Quick Replace Sprocket Coupling on a Screw Drive Operator
Tools are Required:
-Socket wrench/ratchet set
-Cross head screwdriver
-Flat head screwdriver
-Adjustable wrench
-3/8″ socket or 7/16″ socket
Steps to Replace:
1. Disconnect power to your garage door opener
2. Take off the nuts and hex screws from the motor unit bracket
3. Detach the rail from the bracket and slide it backwards
4. Carefully remove the broken coupling, and slide the new one over the rail sprocket
5. Aligning the teeth on the new coupler with the grooves
6. Reattach the rail/power unit bracket with the hex bolts
7. Connect power and adjust the travel and force limits
Warm Note:
The brands related above are only for purposes of demonstrating compatibility, not use as trademarks, our trademark is Dreyoo.